Drying cost is usually quoted per bushel per point of moisture removed. For a high-temperature dryer, the energy part is easy to estimate from your propane and electricity prices.

The factors extension uses

  • Propane: 0.02 gal per bushel per point (University of Minnesota, NDSU); Iowa State uses 0.018, with a range of 0.010–0.025.
  • Natural gas: about 0.0184 hundred cubic feet (roughly 0.0184 therms) per bushel per point, the same heat as 0.02 gal of propane (UMN).
  • Electricity: 0.01 kWh per bushel per point for fans and handling in a high-temperature system.

Energy cost per bushel per point

Propane pricePer bu per point5 points10 points
$1.00/gal$0.0212$0.106$0.212
$1.50/gal$0.0312$0.156$0.312
$2.00/gal$0.0412$0.206$0.412
$2.50/gal$0.0512$0.256$0.512
0.02 gal LP and 0.01 kWh at $0.12/kWh per wet bushel per point.

The long-time rule of thumb of about $0.045 per bushel per point (cited by Minnesota and used in Iowa State A2-32) includes more than fuel at today's prices, so check it against your own records.

Beyond energy

Iowa State's A2-31 adds ownership cost (depreciation and interest over 20–25 years), repairs (about 3% of investment a year), handling (about $0.01/bu) and labor. Divide the yearly fixed cost by bushels dried and points removed to get a full cost per point you can compare with an elevator's drying charge.

Open the drying cost calculator